Posts Tagged ‘the wall’

Length furnace furnace heater must be good. Oposlya the temperature of the walls of the furnace will reach its maximum value, establishes a balance between the heat generated in the oven and bring to the surrounding air. Next burner stove repeated acts to be feasible. Stove persistent acts have to drown unless you want the highest temperature of the stones to produce steam.
Fundamental importance is the size of the fuel line fuel consumption. The larger this size, the greater should be the fuel consumption, so that the combustion process was intense and the share of losses from the output gases was small.
Read the rest of this entry »

Methods of increasing the efficiency of the furnace. To combustible gases going out the firebox, it through the hole in the furnace door pass additional amount of air, called secondary. Without the filing of secondary air occurs khim nedozhog fuel, accompanied by the deposition of soot on the stones (if flue gases are passed through the stones) and in the chimneys. This leads to a decrease of useful heat and the ability of occurrence of fire due to ignition of a layer of soot in the pipes. First, the furnace when the fuel is heated only, and at the end of the furnace when the intensity of the combustion residue of fuel decreases, in the firebox comes extra amount of air. This leads to greater loss of heat from the gases. At the stage of combustion of these losses amount to 20-30%. Lower their method can be covered with holes for air and latches on the chimney. Other factors to increase efficiency furnace acts are increasing the size of the hottest parts, including pebbles, increasing the surface area in contact with the output gases, reducing the thickness and thermal conductivity of the walls of the furnace (for example, by using an alloy), which leads to the most intense heat from the furnace to ambient air.
Read the rest of this entry »

As impenetrable walls used an iron box or metal food kettle pot. The surface of the box and the boiler is washed with hot flue gases, because the stones are heated very quickly. Besieged with refractory brick firebox permits use the stove with coal.
Bricklaying lap. When laying Lap (top of the wall) in order to achieve greater density seams penultimate row of bricks to move relative to the adjacent rows on the width of the weld, and even put it on the penultimate 18-th number of overlapping piece steel roof size 27×27 cm Masonry requires 230 units. bricks.
Read the rest of this entry »

Lower beam crown treated with antiseptic 3-side, wrapped with 3-side ruberoid and placed on the waterproofing. Between the grooves of logs and put the felt to fill the void. If the box windows and doors are placed higher than the surface of the extreme number of logs, you will need preparation is thorns in the lumina of the overlying logs, so they united with the grooved side racks boxes windows.
Asbestos-cement sheets, slates. As shuttering comfortable to use asbestos sheets or slate, lubricating the inner surface of lime milk. At the foundation or on the finished part of the wall formwork sheets set on banjo bolt from the tie bars. The top edges of pages bound between a spacer and fixed in an upright position abutment. Arbolitovuyu mass shuttering laid in layers less than 50 cm in height and tamped. Formwork removed after 2-3 days at air temperature of 18-20 ° C, in a cool time – after 7 days. Bolts removed carefully, rotating them so as not to destroy the wall. Vertical joints between adjacent sections of wall made in the form of sheet-pile connections.
Read the rest of this entry »

The ceiling of the steam room and washing – the board of 55 mm, double insulated
Building material – polished floorboards aspen.
Read the rest of this entry »

The number of panels required depends on the size sweating. In one panel, perform the door with integrated window. With all this height threshold of 20 cm, the size doors 160×60 cm, window size 35×25 cm Window must have double glazing. To ensure the density of the closing bars of the door make a 2-hoo places: the top and bottom. At the bottom of the panel, which has installed an electric hot plate, make a ventilation hole, covered by a valve or plug. Of the 12 panels (10 to 2 for walls and ceiling) gather steam room with internal dimensions of 130×180 cm, which can be fitted with shelves, stove. For sweating with internal dimensions of 130×110 cm with a regiment-bench rather have 10 panels or 8 panels measuring 185×56 cm (for walls) and 1 panel size of 130×150 cm for the ceiling. Seams panels are buried batting and cover both sides of wood planks. The ceiling of the outside cover 2.3 layers of roofing material.
Read the rest of this entry »

For masonry basement digging a trench, deduce it above zero, the filling substance and make pa-roizolyatsiyu a pair of layers of roofing material. Use gravel, rubble stone, gravel, broken bricks, cement and sealed with masonry sand or cement-lime substance. In order to preserve the foundation, it must be protected from rain and surface water. This arranging
The best are those baths, which are built of logs and timbers. The logs are better to choose a similar thickness. The walls of logs and boards hold heat well, they "breathe" – passed steam and air. Even without a pro
Read the rest of this entry »

The condition for keeping the floor and walls is drying them oposlya each use of a sauna. To remove mokrovatogo air from beneath the floor space under the floor to ventilate. The elegant under-floor ventilation is achieved by the location of ash furnace heater below the floor or his message with the underground means easily removable box of tin.
Leaking floor. At the bottom plank gravel and sand, pour concrete. Scat such sex-oriented to one of the walls, in the form of a shallow crater. The mouth of the funnel satisfied with the capacity to collect water (the capacity must be sealed from the concrete rings, bricks, etc.). First, the receiver is prepared for water, and later had himself plank floor. Sex in the steam room and start doing the washing when the foundation was prepared for the fire-stove and drainage system to drain water.
Read the rest of this entry »

Massage the muscle belly especially effective if it create in a prone position, with bent knees. When massaging the abdominal wall exposed to the action of the skin, subcutaneous fat, fascia and muscles of the abdominal wall.
Superficial lymphatic vessels of the upper half of the anterior abdominal wall, the outlet of the lymph covers tummy, fall in axillary nodes, and the lower half of the anterior abdominal wall – in the inguinal nodes. The deep lymphatic vessels, efferent lymph from the deepest layers of muscle and the epigastric region, fall into the intercostal nodes, celiac region – in the lumbar nodes podchrev-term field – in the iliac nodes, which lie along the iliac vessels.
Read the rest of this entry »

Dorozhnik (blade width to 170, a width of 8 to 15 mm along the length of the blade is designed groove depth of 10 mm) is used for sedimentation strands of oakum and giving it the form roller. Good to have three Roadman – for narrow, medium and large grooves.
Foundations make belt and columnar, laying them on the depth of freezing of the ground or at 15-20 cm below the freezing depth.
Read the rest of this entry »